Strengthen Insufficiently RC Columns Reinforcement
Carbon Fiber Rods
Use carbon fiber rods for reinforcement. The addition of carbon fiber rods can work together with existing steel bars to share part of the load, thereby improving the overall bearing capacity of the column.
Problem: The columns of the building have insufficient reinforcement
Solution: Use carbon fiber rods for reinforcement. The addition of carbon fiber rods can work together with existing steel bars to share part of the load, thereby improving the overall bearing capacity of the column. Without increasing the cross-sectional size of the column, the requirements of structural safety are met.
Material: 16mm carbon fiber rods and HM-120CP adhesive
HM-RB16 Carbon Fiber Rebar Technical Data Sheet.pdf